Home >> Product >> Online Transformerless UPS >> RW 1-20KVA

  • RW 1-20KVA
  • RW 1-20KVA
  • RW 1-20KVA
  • RW 1-20KVA
Product name:

RW 1-20KVA

Share

Product parameters

Product Introduction


High frequency RW1-3K&RG6-20K series is based on double conversion  on-line intelligent UPSit adopts advanced DSP digital control technology   has functions of higher output performance indicators and a number of innovative design features   is the ideal solution for small-capacity power supply scenarioscan fully eliminate all kinds of power grid problem. Support for tower or rack-mount installationefficiency can Up to 95%standard UPS need to match battery pack.


Main feature

1.Full digital control technology

2.Output power factor up to 1.0

3.LCD display panel

4.RS232 communication port

5.Intelligent SNMP+USB+EPO+dry contact (optional)

6.High power density design

7.online double conversion

8.External battery pack,rack kits(optional)

9.ECO function


Application

1.Data center 

2.Network device

3.Commercial facility

4.Precision instrument

5.Rack device

6.Telecom system


Specifications 


Model

RW1K

S/L

RW2K

S/L

RW3K

S/L

RG116K

S/L

RG11/3110K

S/L

RG11/3115KL

RG11/3120K

L


Capacity

1kVA

2kVA

3kVA

6kVA

10kVA

15kVA

20kVA


Input features

InputVac

120300

120300(1/1)/266-475(3/1)

FrequencyHZ

4566 Automatically select synchronization range according to grid frequency

Phase

Single phase

Single phase /3φ4W+PE

Power factor

Full load≥0.95

Full load≥0.98

Battery voltageVdc

 

24/36

 

 

48/72

 

72/96

 

192

Battery type

 

 

2*9Ah 12V/Exte  rnal

 

 

 

4*9Ah 12V/

External

 

 

6*9Ah 12V/External

 

 

 

16*9Ah

12V/External

 

 

 

 

16*9Ah

12V/External

 

 

 

 

 

External


Output features

Power factor

1.0

Voltage(V)

220/230/240±1%

Frequency(HZ)

50/60±0.05%battery mode

Transfer timems

0

Efficiency (AC mode @ full loads)

≥92%

≥93%

Waveform

Linear Load THD<3%Non-linear Load THD<5%

Overload capacity

105%~129% full load keep 60s130%~150% load keep 30s

Above 150% load keep 300ms

105%-125%,transfer to bypass after 10 mins; 125%-150%, transfer to bypass
after 30secs;
30 second, cut off input after 1 min;>150%,transfer to bypass after 0.5 second

Crest factor

>3:1

Others features

DC start

Yes

Backup time

Long backup time, can be extended freely

Charge recovery time

 

Determined by the extended battery capacity

Communication function

RS232(USB/dry contact are optional)

SNMPOptional

 

Can be network monitored by SNMP adapter

Display

LED display UPS work status, LCD display UPS work parameters

Noise (dB)

<50(within 1 meter)

<55(within 1 meter)

Parallel function

No

Yes(optional)

Alarm

Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection

Protection

Input over-voltage protection, battery under-voltage protection, overload protection, short circuit protection, over temperature protection

Working temperature

 

040

Humidity

095%Non condensing

Size(D×W×H) (mm)

 

 

 

375×440×88(2U)

 

 

612×440×88(2U)/375×440×88(2U)

612×440×130(3U)

1/1: 612×440×130(3U)/ 3/1:700×440×130(3U)

660×440×260(6U)


Weight(KG)

14/7

29 /9

33 /10

55 /19

57/21(1/1)

57/22(3/1)

 32

38



Note:

  1. “L” is long backup UPS,“S” is standard UPS;

  2. Because the products are continuously improved, please contact the company or dealer to inquiry the latest specification.